Low Maintenance Cost, Minimum Of A Hassle with UVENT ICU Ventilators
Certainly, all the intelligent modes, comprehensive monitoring as well as the cutting-edge maneuvers and tools are very important for a modern ICU ventilator. But we also need to pay attention to some practical engineering solutions for optimizing device maintenance and post-sales support. After all, exact they can subsequently make routine easier for end-users and save money during years of operation of the device. It is not only about saving money on maintenance. But also about saving time: on technical work, calibration, adjustment etc. The most importantly, such a solution can significantly reduce the time when the ventilator will be out of order and unable to help save lives.
That is why in UVENT™ ICU ventilators, among other things, we paid attention to reducing the number of required consumables, minimizing the hassle and time for routine support and troubleshooting.
Minimum of consumables and a hassle
With UVENT™ you get permanent ultrasonic oxygen sensor that does not require regular calibration and replacement, and it is offered with lifetime warranty. This type of sensors is durable and provides continuous, stable and accurate O2 monitoring even in humid environments.
UVENT-T and UVENT-M models have a built-in high performance low-noise turbine. It requires no special maintenance during the whole period of operation, which significantly simplifies maintenance of UVENT ventilators. Moreover, high flow velocity and low noise operation maintaining a comfortable environment for medical staff and patients.
UTAS has developed an innovative technology REMOTE UVENT to provide efficient support and timely service. It allows service engineers to perform remote diagnostics, adjustment, and software update remotely from any location simply through the Internet. This solution can reduce traveling cost, diagnostic and shipping time for rapid and effective servicing. No more long waiting time to get your device back in ward.
Illustrated automatic testing of internal systems, sensors, and breathing circuit performance in UVENT may facilitate early detection of possible malfunctions. It also reduces the risk of errors due to the human factor. The device can pass through a full or quick test depending on the situation and service requirements.
Stable performance of the ICU ventilator
In addition to reducing potential post-sales maintenance cost UVENT is designed for stable and long-term operation. Durable aluminum case, compact size and up to 4 hours ventilation with Li-ion built-in battery, automatic altitude, compliance, leak and resistance compensation — all this guarantees stable, reliable operation, both in short and long-term respiratory support of the patient.